conMIG 400/445/545
Operating manual
Page 40
The values can be changed by rotating the left knob.
If the value is not changed for more then 2 seconds, the value will be stored.
During welding:
Operation mode MIG:
During the welding operation, the choc function is accessed and can be modified by tapping the button Fx.
The left display shows Choc, in the middle display is the current value.
Now, with the left knob, the value can be changed.
By another tap on the Fx button, the wire speed correction is shown in the middle display and the LED % is
light. Now, with the left knob, the value can be changed (between -50% and +50%).
Function
►
MC 4-5
In stand-by mode (not during welding):
By tipping short on the control key
►
the following functions can be changed for
each welding
curve
(only in stand-by mode):
Operation Mode MIG:
- choke (Display Choc – only MC4): step less correction of the welding choke
from ‚- 80 harder’ to ‚+ 80 smoother’ then normal ‘0’
- start - speed (StS):
10 to 100% of the welding speed
- wire burn back (bUb):
-60ms (long, pointed) to +90ms (short, ball wire end)
The values can be changed by tipping on the keys
▲
or
▼
.
If the value is not changed for more then 2 seconds, the value will be stored.
During welding:
Operation mode MIG:
During the welding operation, the choc function is accessed and can be modified by tapping the button
►
.
The left display shows Choc, in the middle display is the current value.
Now, with the middle knob, the value can be changed.
By another tap on the
►
button, the wire speed correction is shown in the middle display and the LED % is
light. Now, with the middle knob, the value can be changed between -50% and + 50%.
To block the control unit - CODE (MC 3)
To block the control unit:
Tip on key Fx as long as ‘CodE’ appears in the display. Now rotate the left rotating knob to a number
between 0000 and 9999.
If the right number is in the display press the key ‘wire-feed-in’. Now the control unit is blocked. Only the
functions gas test, wire-feed-in and wire-speed correction are available. All other functions are blocked.
To unlock the control box, tip again on the Fx key, until ‘CodE’ appears.
Now rotate to the same number, as for blocking. After tipping on the key ‘wire-feed-in’ the control unit is
unlocked.
Option Fx (MC 3)
To adjust the low-level basic settings, press the control key ‘Fx’ for more then 1 second. The following
options can be changed:
- EC 1/2: Specify the functions of the remote control potentiometer (see next page)
- Hold: adjust the time for the display hold (0 = endless, -> 25s)
- Reset the jobs or factory settings (see next chapter)
- Torch type and length set: tap until ‚tch’ appears in the left display,
in the middle display the following 3-digit numeral appears:
1st digit: 1 = gas cooled torch, 2 = water cooled torch
2nd + 3rd digit: length of the torch (2, 3 or 4m)
adjust with the rotating knob exactly the mounted torch
e.g.: 204 = water cooled torch with 4m length
- Remaining cable length set (earth cable and perhaps torch hose package)
tap until ‚cbl’ appears in the left display, now adjust the complete cable length
(without torch cable length!) in the right display.
Summary of Contents for conMIG 400
Page 2: ......
Page 28: ...conMIG 400 445 545 Operating manual Page 25...
Page 54: ...conMIG 400 445 545 Operating manual Page 51 Seitenansicht links sideview left...
Page 56: ...conMIG 400 445 545 Operating manual Page 53 Seitenansicht rechts sideview right...
Page 58: ...conMIG 400 445 545 Operating manual Page 55 Koffer wire feed case DVK 3 2010...
Page 61: ...conMIG 400 445 545 Operating manual Page 58 Koffer wire feed case DVK 4 2010...
Page 71: ......