background image

第 8页共 10 页

P 9 1

0~70

50

Maximum stitch

P 9 7

0~2

0

Voice broadcast mode selection (0-power on language and press on voice 1- power on language
only - press on voice only)

P 9 8

0~7

7

Voice volume

P 9 9

0~2

1

Voice selection (0- Voice off 1- Country 1- Country 2- Country 2)

P 1 0 0

0~9999

0

Free - seam and multi - seam ABCD segment ten - position compensation

P 1 0 1

0~9909

0

W seam ABD section ten section compensation

P 1 0 2

-99~99

2

Reduce/add the number of stitches in the first section of W seam

P 1 0 3

-99~99

2

Reduce/add the number of stitches at the end of W seam

P 1 0 4

0~9999

0

Stitch count current value

P 1 0 5

0~9999

0

Number of pieces counts the current value

P 1 0 6

1~50

1

A unit for counting the number of stitches

P 1 0 7

0~9999

9999

Stitch count set point

P 1 0 8

0~6

0

Stitch count mode

P 1 0 9

1~50

1

A unit of count

P 1 1 0

0~9999

9999

Number of pieces count set value

P 1 1 1

0~6

0

Number of pieces counting mode

4.2 Monitor mode

No.

Description

No.

Description

M 0 1

Feedback value of spindle speed

M 2 5

The ratio between motor and machine

M 0 2

On the AD value

M 2 6

The total used time(hours) of motor

M 0 3

The step zero

M 2 7

Software version L

M 0 4

busbar voltage

M 2 8

Software version H

M 0 5

The spindle zero

M 2 9

Analog input 1

M 0 6

Step encoder value0~4000

M 3 0

Analog input 2

M 1 5

Spindle encoder value0~2880

M 4 0

Analog input 3

M 1 6

Dump switch IO port value

M 4 1

Analog input 4

M 1 7

Reverse seam switch IO port value

M 4 2

Parameter version

M 1 8

Fill half needle switch IO port value

M 4 3

The history records of error codes

M 1 9

IO port value of stitching switch

M 4 4

Panel BOOT version number

M 2 0

Servo motor overcurrent fault detection port

value

M 4 5

Motherboard BOOT version number

M 2 1

Stepper motor overcurrent fault detection port

value

M 4 6

Main board APP version number 1 XXYY:XX represents

year and YY represents month

M 2 2

Oil level detects port value

M 4 7

Main board APP version 2 XXYY:XX stands for date and YY

stands for time

M 2 3

Initial electric Angle value of spindle motor

M 4 8

Version 1 of APP on the panel XXYY:XX represents year

and YY represents month

M 2 4

Mechanical Angle value

M 4 9

Panel APP version 2 XXYY:XX represents the date and YY

represents the time

Summary of Contents for A7

Page 1: ...r properly and safely qualified engineers are required Please stay away from arc welding equipment in order to avoid electromagnetic interference and malfunction of the controller Keep room temperatur...

Page 2: ...f operation panel will display the current sewing mode parameters start end back tacking and presser foot needle position soft start sewing etc Function mark of the operation panel is as follows 1 2 3...

Page 3: ...ng pressed toggle the presser foot function on or off The trajectory of key If click switch the current sewing track 1 4 cycle switch track description Track 1 standard track to reduce fabric sliding...

Page 4: ...voice version V2 represents the recovery code Presser foot key 1 Short press key the icon of LCD is lit the c sewing after the end of automatic trimming presser foot function turns on 2 Long press Key...

Page 5: ...to fully over stalk 3 2 Thin material thickness setting 1 Long press the Thin Thickness Test key to enter the Thin Thickness Test Setting Interface stop the needle to the stop position the needle plat...

Page 6: ...ous stitching according to the time 2 half stitching 3 one stitching P 1 6 0 9999 0 Thickness detection 0 point value P 1 7 0 9999 0 Thick material height P 1 8 0 50 5 A terrier number of threads P 1...

Page 7: ...he Angle relative to Z signal P 5 9 0 359 160 Lower stop needle to adjust the Angle relative to upper stop needle P 6 0 200 5000 4000 Automatically test running speed P 6 1 0 1000 500 Electric Angle v...

Page 8: ...e ratio between motor and machine M 0 2 On the AD value M 2 6 The total used time hours of motor M 0 3 The step zero M 2 7 Software version L M 0 4 busbar voltage M 2 8 Software version H M 0 5 The sp...

Page 9: ...circuit failure Turn off the system power and turn on the power again after 30 seconds to see whether it can work properly Try a few times again If the fault occurs frequently please contact your loc...

Page 10: ...g and restart Please contact your local service provider or call 4008876858 Err 32 Backstitch step motor hardware overcurrent 1 Turn off the system power and then turn on the power again after 30 seco...