第 5页共 10 页
2.3.5 Piece/stitch count setting
In the power-on state, press
+
key to enter piece/stitch count interface. Use the Left/Right key to switch between the piece/stitch count.
2.3.6 Step motor “Zero” calibration
When the machine is on, adjust the needle distance to 5mm, press
the key to enter the user parameter mode, adjust the parameter to P123,
measure with ordinary A4 paper, adjust the parameter to make the continuous needle distance reach the same length;
Note:When entering the interface of parameter P123, the speed will automatically drop to 200rpm. After leaving this interface, the speed
will return to normal.)
2.3.7 Stitch length adjustment setting
When the machine is on, set the needle distance to 5 mm.Button to enter user parameter model, the parameters to P112 (track 1 suture needle
distance compensation), P114 (track 2 stitches distance compensation), P116 (track 3 stitches distance compensation), P118 (track 4 stitches
distance compensation), in ordinary A4 paper paper test, measure distance between two pinhole on the paper,adjust the parameter to stitch 4.9
5.1 mm.Then enter P113 (track 1 reverse stitching distance compensation), P115 (track 2 reverse stitching distance compensation), P117 (track 3
reverse stitching distance compensation), P119 (track 4 reverse stitching distance compensation), use ordinary A4 paper, stitch a section forward,
press and hold the manual reverse stitching switch, adjust the parameters, make the reverse stitching overlap more than 11 stitches.
Note: When entering the P112-P119 interface, the speed will automatically change to 200 RPM for easy debugging. After leaving the interface,
the speed will return to normal.
3 Thin thickness detection parameter model description
3.1 Thin thickness detection function description
For the requirements of over-stalk in the sewing process, when the thickness detection is turned on, when the cloth suddenly thickens, it will slow
down according to the setting, and the needle distance will change to fully over-stalk.
3.2 Thin material thickness setting:
1
)
Long press the Thin Thickness Test key to enter the Thin Thickness Test Setting Interface, stop the needle to the stop position (the needle plate
with teeth exposed), and place the thinner part of the cloth;
2
)
Click +/- to select item H01, and long press P to display "H01 ----" on the panel;
3
)
Wait until the panel displays "OK" and the voice announces "successful identification of fabric thickness". After about 0.8s, "H01-DD-SS" is
displayed (DD stands for real-time height and SS stands for set height). At this time, thin material thickness identification is completed, and the AD
value identified is stored in P25.
pay attention to
:
If the height of thin material identification is larger than the set value of thick material thickness, it shows that ER is about 0.8S,
indicating that the setting fails;
3.3 Thick material thickness setting:
1) Long press the Thin Thickness Test key to enter the Thin Thickness Test Setting Interface, stop the needle to the stop position (exposed needle
plate with teeth), and place the thicker part of the cloth;
2) Click +/- to select item H02, long press P to display "H02 ----" on the panel;
3
)
Wait until the panel displays "OK" and the voice announces "successful identification of fabric thickness". After about 0.8s, "H02-DD-SS" will be
displayed (DD stands for real-time height and SS stands for set height). At this time, the thickness identification of thick material is completed, and
the AD value identified is stored in P17.
pay attention to
:
If the height of thick material identification is smaller than the set value of thin material thickness, it shows that ER is about 0.8S,
indicating that the setting fails.
3.4 Corresponding parameter table of thickness detection and adjustment:
Parameter Item
Corresponding parameters
significance
explain
H03
P18
A terrier number of threads
Factory
:
5
H04
P19
A terrier speed
Factory
:
2000
H05
P20
Compensation value of over-stalk needle
distance
Factory
:
5
;
Displays the needle spacing icon
H06
P21
Thickness detection sensitivity
Automatic/manual setting when identifying cloth
thickness
H07
P22
A terrier trajectory
Factory
:
Track 4
;
Display the corresponding track icon