第 7页共 10 页
P 3 9
0~4000
0
Front reinforcement/W seam second stitch speed limit
P 4 0
0~4095
900
The position of the rear half step (presser foot lifted) of the pedal
P 4 1
0~4095
1600
Pedal analog return to the median
P 4 2
0~4095
300
Start position of low speed running in front of pedal (relative median)
P 4 3
0~4095
600
End position of low speed running in front of pedal (relative median)
P 4 4
0~4095
4000
Maximum pedal analog amount
P 4 7
200~360
359
Back-pull function after cutting wire
P 4 8
0/1
0
Lift presser foot switch in advance when cutting wire
P 4 9
100~500
250
Shear velocity
P 5 0
100~500
200
Lifting foot solenoid total output time
P 5 1
0-9999
0
Thin height
P 5 2
10~500
50
Running delay time of presser pin motor
P 5 3
0/1
1
Presser foot switch
P 5 4
0~255
5
Automated test run times
P 5 5
0~255
3
Automatic test stop time
P 5 6
0/1
1
Switch on the power to find needle position automatically
P 5 7
1~60
10
Protection time of solenoid in lifting foot
P 5 8
0~359
275
Stopping needle to adjust the Angle (relative to Z signal)
P 5 9
0~359
160
Lower stop needle to adjust the Angle (relative to upper stop needle)
P 6 0
200~5000
4000
Automatically test running speed
P 6 1
0~1000
500
Electric Angle value
P 6 2
0-3
0
Operation mode (0- normal sewing 1- easy sewing 2-THETA0 test 3- automatic test)
P 6 3
0/1
0
Start tight slot switch
P 6 4
0/1
65
Stop the tight slot switch
P 6 6
0/1
1
safety switch
P 6 7
0~3000
0
Look for the Angle of the principal axis
P 6 8
200~5000
3800
Free seam maximum speed limit
P 6 9
0~359
150
Spindle delta Angle
P 7 1
50~350
104
Soft release time of solenoid in lifting foot
P 7 2
0/1
1
Anti-breaking needle function switch
P 7 4
100~2500
1000
Initial tight seam velocity
P 7 5
0~12
2
Number of initial tight stitches
P 7 6
100~2500
1800
Stop tight seam speed
P 7 7
0~12
2
Stop the number of tight stitches
P 7 8
10~359
130
Clamp starting Angle
P 7 9
0~359
320
Clamp end Angle
P 8 4
200~3000
2000
Pattern sewing speed
P 8 5
0/1
0
Multi - slit pattern switch
P 8 6
0~50
8
Start close stitching distance
P 8 7
0/1
1
The direction of the initial tight seam
P 8 8
0~50
5
Stop close stitching
P 8 9
0/1
1
End the direction of the tight seam
P 9 0
0/1
0
Lock pin distance switch (0-- off 1-- on)