Light management
The unit features a retractable vari-focus system to allow a tightly focused spot beam
or a diffused flood of light so any working environment can be catered for. Use the two
control knobs either side of the light head to move the diffuser blind up and down in front
of the LEDs, as the blind gradually passes over the LEDs you’ll notice the projected light
pattern change.
SOS Mode
The unit may be set to flash the LED’s in the SOS sequence if the need ever arises. To
do this, switch on, select the power level (brightness) you wish to use (8%,25%,
50%, 75%,100% or 125%). Next press the MODE button twice, pressing the SELECT
button allows the inner outer or both channels of LEDs to be run.
Flashing Mode
The unit may be set to constantly flash the LEDs to provide a warning signal to oth-
ers. To select this option first switch on, select a power level you wish to use (8%,25%,
50%, 75%, 100% or 125%) then press the MODE switch once, pressing the SELECT
button allows the inner, outer or both channels of LED’s to be run.
Battery Status Indication
A low battery warning with cut-off function is included with your Series 60 LED to pre-
vent deep discharging the high performance cyclic SLA battery. Deep discharging can
lead to reduced battery performance and life.
The user is signalled to help pre-warn of the amount of energy left in the battery able to
run the LED light in 3 ways: 3 colour LED, audible bleeper and flashing of the LEDs on
the main panel. As the fully charged battery discharges the indicator LED (located next
to the power on/off switch) will show green.
As the battery discharges further this indicator LED will change from green through to
amber, at this point the unit will give an audible bleep and blink the main LEDs once to
alert the user that a stage has been reached in the discharge process.