For Your Safe Flight
Page 45
2.
Flight
Fuel USED shown by EDM
(total tank - REM)
Actual fuel used by topping tanks
1
2
3
Total
Œ
•
2. Total
Œ
the EDM fuel used and
•
the actual fuel used.
3. Record the current K factor here
Ž
____________________ and in
the table below.
4. Calculate the New K Factor as follows:
New K Factor = (
Œ
EDM fuel used)
x
(
Ž
Current K factor)
(
•
actual fuel used)
New K Factor = (
Œ
)
x
(
Ž
)
(
•
)
Every time you fine tune the K factor, record the measurements here:
Date
Œ
EDM
fuel used
•
actual
fuel used
Ž
Current K
factor
New K factor
=
Œ
x
Ž
/
•
Pilot’s
initials
Fuel Flow Option Programming Procedure
Setting the K factor
This procedure is different than for setting other parameters. Place the
select switch in the
FF
position. If you haven’t already done so, start the
pilot programming procedure, simultaneously hold the
STEP
and
LF
buttons for five seconds. You will see the word
PROGRAM
for two
seconds.
1.
Tap
STEP
button to advance to the KF-SET screen
29.00
=
KF
2.
Hold both the
STEP
and
LF
buttons simultaneously for five seconds.
First digit flashes (shown here as a larger digit only for illustration
purposes):
2
9.00