![iWeld DYNAMIG 560 User Manual Download Page 189](http://html1.mh-extra.com/html/iweld/dynamig-560/dynamig-560_user-manual_2098556189.webp)
HU
EN
61
Main
display
Second
display
Description
Causes
Action
ALL/SC
Err: 60
Alarm short circuit.
Occurs when short circuit in the output.
"1) Output cable in short circuit, check outside the machine. 2) Ask to the Service Center"
ALL
Err: 63
Output voltage lower than expected
"1) Check the connections to the external wire feeder 2) Wrong calibration of the output voltage. Try to download the default calibration. 3) Failure in the main board T178"
Shut off and switch on the machine, if the alarm comes again, please ask to the Service Center.
ALL/THC
Err: 70
Thermal cycle alarm over use of the machine.
1) Machine is connected to automatic equipment and its usage is more than the maximum.
2) The machine has poor cables and the output voltage drop in these cables is consistent.
3) Wrong calibration of the machine.”
1) Check the name plate maximum usage levels in term of current voltage and duty cycle
2) Check the accessory cables and torch.
3) Check the calibration or replace the main con- trol board.”
ALL
Err: 90
Pre-charge alarm
1) Power transistor broken.
2) Electrolytic capacitors broken.
3) Missing connection of the DC BUS to the invert- er board. Auxiliary connection between inverter board and interface board not well connected."
If the electrolytic capacitors cannot be charger, the alarm occurs.
Summary of Contents for DYNAMIG 560
Page 1: ...CUTTING EDGE WELDING R HASZN LATI TMUTAT DYNAMIG 560 MIG MAG hegeszt g p...
Page 65: ...CUTTING EDGE WELDING R BEDIENUNGSANLEITUNG DYNAMIG 560 MIG MAG Schwei ger t...
Page 129: ...CUTTING EDGE WELDING R USER S MANUAL DYNAMIG 560 MIG MAG Welding Power Source...
Page 195: ...HU EN 67...
Page 196: ...www iweld hu...