- 39 -
■
Assembly
Assembly is done in reverse order to
disassembly. Pay attention to the fol-
lowing points.
•
Pay attention to arrangement of the
valve set. Wrong arrangement and
direction will cause failed pumping
(liquid leakage, decreased discharge
capacity).
•
Be sure to mount the O ring and
gasket.
1)
Mount the discharge side valve
set
Put the valve set in the pump head.
Then screw the fitting in the pump
head by hand. Tighten the fitting
by 1/4 turn with a spanner in the
last place.
2)
Mount the suction side valve set
Put the valve set in the fitting (3)
and screw the fitting into the pump
head by hand. Then tighten it by
1/4 turn with a spanner.
Maintenance
Caution
Pay attention not to drop
the valve set.
Suction side
3
28
11
13
12
28
11
13
12
14
28
28
Valve set
3
28
11
13
Discharge side
12
28
11
13
12
14
28
28
Valve set
Arrangement of
the discharge side valve
Arrangement of
the suction side valve