- 7 -
Outline of product
5. Operating function
5-1. Manual operation
Pump operation
Operation
Operation
Stop
Key operation
Use (UP) and (DOWN) keys to set a stroke rate between 1 ~
360 spm. Use
(Stop/start) key to start/stop the pump. Stroke rate
can be adjusted when the pump runs or stops.
EXT input(Multiply) ×n operation (n=5)
External pulse
Pump operation
1 2 3 4 5
1 2 3 4 5
EXT input operation (Pulse multiply)
Pump operates with a set number of pumping between 1~999 for a
external pulse signal. The preset stroke rate in manual operation is
applied as the upper limit stroke rate in EXT operation. The pulse
signals which come while pumping for the set number of times for
a external pulse signal are stored up to 255 pulses. When the set
number of pumping is set to 1, pump operates synchronously with a
external pulse in the ratio of 1:1.
5-2. EXT operation
EXT input (Multiply) when a set number of pumping is 5
EXT input (Dividing) when a set number of pumping is 5
EXT input operation (Pulse dividing)
Pump operates with a pumping for external pulse signals. The preset
stroke rate in manual operation is applied as the upper limit stroke
rate in EXT operation. Residual input signals over 360 spm are
cancelled. When the set number of external signals is set to 1, pump
operates synchronously with a external pulse in the ratio of 1:1.
Caution
When the set number of external pulse signals for a pumping
is set to 1 in pulse dividing operation, pump operation can be
unstable due to the residual signal cancellation function but it
is not malfunction of pump. Set the number of pumping for a
external pulse signals to 1 for 1:1 operation in the pulse multiply
operation.
EXT input(Dividing) /n operation (n=5)
External pulse
Pump operation
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5