Outline of product
ON
STROKE R ATE
Start/Stop key
Use this key to
start/stop the pump.
ON lamp
Lits when
power is ON
and blinks
synchronously
with each
stroke.
Down key
Push this key to
change mode or
setting value.
Display
Operation state or
each setting value are
displayed.
Up key
Push this key to
change mode or
setting value.
7-2. Overview of controller
- 9 -
7-3. Basic display.
ON lamp lights.
ON lamp blinks.
The pump is waiting in
manual operation mode.
The pump is running in
manual operation mode. The
stroke rate blinks, too.
The pump is in EXT mode.
EXT setting can be done.
The pump is running in EXT
mode.
The pump is stopped by
STOP signal..
The pump is stopped in
manual waiting mode while
STOP signal comes.
Chattering is being set.
T-10 or T-50 is displayed
other than T-5.
STOP function is set to
M-OF. M-ON is displayed
when M-ON is selected.
The multiply ratio of EXT mode
is being set. The left display
shows 5 pumpings for a pulse.
EXT input signals exceed the
pump upper limit spm in EXT
mode. Pump operates at its
upper limit spm.
Pulse multiply mode is
selected in EXT setting.
The dividing ratio of EXT mode
is being set. The left display
shows 1 pumping for 5 pulses.
Pulse dividing mode is
selected in EXT setting.
Pump is running in pulse divid-
ing/multiply operation for exter-
nal input pulses. The indication
shows spm.
( )
Key is locked. Key opera-
tions are ineffective in this
state. Release the key lock
function before operation.
ON lamp lights
ON lamp blinks
Key is locked. Key opera-
tions are ineffective in this
state. Release the key lock
function before operation.