- 12 -
4m
Rubber plate
2. Installation/Piping/Wiring
■ Installation
1.
Select an installation location where is con-
venient for maintenance. Ambient temperature
should not exceed 40
º
C or falls below 0
º
C.
Observe the maximum ambient humidity of
85%RH. Do not install the pump out of doors.
CAUTION
When installing the pump, be careful not
to impact the pump. A strong impact may
adversely affect pump performance.
The pump can be mounted either verti-
cally or horizontally. A flow direction can be
reversed by inverting motor rotation.
2.
The maximum
suction lift is 4 meters based on
operation with clean water and changes accord-
ing to liquid characteristics.
3.
Fix the pump with M5 screws. Place a rubber
plate beneath the pump base to reduce noise or
oscillation as necessary.
Installation
Summary of Contents for Hicera V Series