- 8 -
4. Specification
50/60Hz
Outline
Model
Gear ratio Speed (rpm) Max. flow
(ml/min)
Max.press.
(MPa)
Tube joint
(mm)
Standard
motor
Mass
(kg)
V-05SL1A5
1/150
9/11
1.6/1.9
0.7
ø6 SUS
tube joint
Induction
motor
100VAC 15W
2.3
V-05SL1B5
1/75
19/23
3.3/4.0
V-10�L1A5
1/150
9/11
6.0/7.0
V-10�L1B5
1/75
19/23
13/16
V-10�L1C5
1/30
48/58
33/40
V-10�L1D5
1/15
96/116
67/81
V-10�L2E5
1/7.5
193/232
135/163
0.6
ø10 SUS
tube joint
Induction
motor
100VAC 25W
3.0
V-10�L2F5
1/5
290/348
203/245
0.4
V-10�L2G5
1/3
483/580
338/409
0.3
V-15�S3E5
1/7.5
193/232
559/673
0.5
ø13 SUS
tube joint
Induction
motor
100VAC 40W
8.0
V-15�S3F5
1/5
290/348
841/1009
0.3
V-15�S3G5
1/3
483/580
1400/1682
0.2
● Either A: AL
2
O
3
/AL
2
O
3
or S: SiC/SiC comes in :
● Performance values in the above table are based on pumping clean water at ambient temperature.
● The revolution per minute is based on use of clean water and varies with liquid characteristics.
● Discharge capacity per revolution when the pump head is at an angle of 20º.
Approx. 0.17ml/rev for V-05
Approx. 0.7ml/rev for V-10
Approx. 2.9ml/rev for V-15
● The maximum suction lift with clean water is 4 meters and varies with liquid characteristics.
● Flush out crystallizing or adhesive liquid from the pump head after operation. Use of the pumps with flush-
ing ports is recommended.
Summary of Contents for Hicera V Series
Page 7: ...5 Outline 1 Unpacking Inspection 6 2 Product outline 6 3 Model code 7 4 Specification 8...
Page 11: ...9 Installation 1 Before installation 10 2 Installation Piping Wiring 12...
Page 16: ...14 Operation 1 Operation 15...
Page 19: ...17 Maintenance 1 Disassembly Assembly 18 2 Troubleshooting 24 3 Dimensions 25 4 Wear parts 27...
Page 30: ...28...
Page 31: ...29...