56 Operation programming
Push the start/stop key to return to manual mode.
Display selection
Either "EXT" or "spm" indication is selected for EXT mode.
EXT indication appears when "EXT" is selected. A stroke rate appears when a
spm indication is selected.
NOTE
• The spm indication shows a current stroke rate. The number of external pulse signals
is not shown on the screen. Note that the stroke rate shown in EXT mode is an calcu-
lated spm and doesn't re
fl
ect a current spm exactly.
• Do not enter the EXT signal during the programming.
Enter EXT mode.
• Push the DOWN key while pressing the start/stop key to move from
manual mode to EXT mode.
• Push the start/stop key and stop the pump when the pump is running.
Then call up EXT mode.
ON
STROKE RATE
ON
STROKE RATE
ON
STROKE RATE
ON
STROKE RATE
4
1
Summary of Contents for EHN-R