52 Operation programming
Push the start/stop key to return to EXT mode.
The pump runs according to the multiplier programming.
Divider programming
Program the number of signals per shot to control the pump. The number of
signals can be programmed from 1 to 999.
NOTE
• If a divider is programmed to 1 to make 1:1 operation and the input interval of the
external signal is close to a manual operation spm (but not exactly in synchronization),
irregular operation may occur. This irregular operation occurs as the external signal
is cancelled. Note that this is not malfunction. In order to avoid this phenomenon,
perform 1:1 operation by programming a multiplier to 1.
• Do not enter the EXT signal during the programming.
Enter EXT mode.
• Push the DOWN key while pressing the start/stop key to move from
manual mode to EXT mode.
• Push the start/stop key and stop the pump when the pump is running.
Then call up EXT mode.
ON
STROKE RATE
ON
STROKE RATE
ON
STROKE RATE
7
1
ON
STROKE RATE
Summary of Contents for EHN-R
Page 91: ...91...