48 Operation programming
NOTE
• Manual operation spm is applied as the EXT upper limit spm. For example, even if
the external signal is entered to run the pump at 360spm, the pump does not run over
200spm as long as manual operation spm is 200rpm
• A stroke rate skips from 360spm (300spm for the VH/PH-V) to 1spm by pushing the
UP key once. Pay attention to this point when programming a stroke rate.
Enter manual mode.
Enter the manual mode to indicate spm on
the screen.
•
Push the start/stop key when "EXT" or ".0"-
".360" is on the screen.
•
When "STOP" or "-STOP" appears on the
screen, see "STOP function cancellation"
on 60 page and release the STOP function.
Use the UP or DOWN key to program the upper limit spm.
Push the start/stop key and stop the pump when the pump is running.
Then program spm.
•
spm increases/decreases as pushing the UP/DOWN keys.
•
Press and hold either key for more than three seconds for quick
change. Quick change stops at 1 or 360spm. 1 or 360rpm skips to 360
or 1 spm when the key is released and pushed again.
*Programmable range is 1-300spm for the VH/PH-V.
ON
STROKE RATE
ON
STROKE RATE
Push the UP key
Push the DOWN key
2
1
ON
STROKE RATE
Summary of Contents for EHN-R
Page 91: ...91...