23
Ins
tal
lation
Pipework
Connect an air bleed tube into the
air vent port.
Place the tube end in the supply
tank or another container.
Direction of the air vent port.
The air vent port can rotate 90 de-
grees.
a. Turn the lock nut anticlockwise.
b. Adjust the direction of the air vent
port.
c. Turn the lock nut clockwise and
fi
x
it, holding the air vent body A.
d. Further tighten the lock nut by turn-
ing it 90 degrees with an adjustable
wrench or spanner.
NOTE
The air vent port is not provided to the EHN-
31•36 and FC types. Install an air vent valve.
See the right diagram. Optional air vent valves
are available except for the FC type. See page
86 for detail.
2
3
Tube
Outlet
Lock nut
Air vent valve
Three way joint
Air vent body A
Air vent
valve
Check valve
Discharge line
Pump
Summary of Contents for EHN-R