40 Before operation
Turn on power and call up manual mode.
Enter manual mode to indicate spm on the
screen.
• Push the EXT key when "EXT" or ".0"-
".360" is on the screen.
• When "STOP" or "-STOP" appears on the
screen, see "STOP function cancellation"
on 60 page and release the STOP function.
Use the UP or DOWN key to adjust stroke rate.
• spm increases/decreases as pushing the UP/DOWN keys.
• Press and hold either key for more than three seconds for quick
change. Quick change stops at 1 or 360spm. 1 or 360rpm skips to 360
or 1spm when the key is released and pushed again.
*Programmable range is 1-300spm for the VH/PH-V.
Push the start/stop key.
The LED and spm indication blink as the pump starts to run.
• They blink in sync with the pump operation.
ON
STROKE RATE
ON
STROKE RATE
ON
STROKE RATE
ON
STROKE RATE
ON
STROKE RATE
2
3
1
Push the UP key
Push the DOWN key