60
Step 4:
Load the furnace.
Now, open the furnace head using the OPEN FURNACE HEAD key and position the firing tray with the object in the
furnace.
Step 5:
Start the program.
Activate the program by pressing the START key. The LED lights up in
green. The process is indicated in the firing curve display.
The furnace head opens automatically at the end of the program.
When the Optical Status Display lights up in green, the furnace is
ready for the next program start.
Step 2:
Select the operating mode.
After the self-test has been completed, the selection of the operating
modes is displayed. Select the operating mode "Firing".
Step 3:
Select the program.
Press the
[Individual Programs]
button.
6. Practical Use
6.2 Firing procedure with an individual program
Step 1:
Switch the furnace on.
Switch the furnace on using the mains switch at the back of the
furnace. Subsequently, the furnace conducts an automatic self-test.
Wait until the furnace has reached the pre-set stand-by temperature.