Figure 7
Engine oil level sensor
This sensor is used to indicate that the sump oil level is too low.
Features:
- max pressure
:
5 - 28 Vdc
. . . . . .
- resistance
130 mA a 28 Vdc Max
. . . . . . . . . .
- work temperature
-40
˚
C / + 125
˚
C
. . .
- Tightening torque
10 ± 2 Nm
. . . .
A. Electrical contact in open position — B. Electrical contact in close position - low level in the oil sump
SECTION 3 - INDUSTRIAL APPLICATION
49
VECTOR 8 ENGINES
Print P2D32V001E
Base - April 2006
Summary of Contents for VECTOR 8
Page 1: ...VECTOR SERIES Industrial application VECTOR 8 Technical and Repair manual ...
Page 10: ...2 VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 14: ...6 VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 16: ...2 SECTION 1 GENERAL SPECIFICATIONS VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 18: ...4 SECTION 1 GENERAL SPECIFICATIONS VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 28: ...14 SECTION 1 GENERAL SPECIFICATIONS VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 30: ...2 SECTION 2 FUEL VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 60: ...8 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 62: ...10 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 94: ...42 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 96: ...44 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 106: ...54 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 108: ...56 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 130: ...78 SECTION 3 INDUSTRIAL APPLICATION VECTOR 8 ENGINES Base April 2006 Print P2D32V001E ...
Page 192: ...2 SECTION 5 TOOLS F4AE NEF ENGINES Base April 2006 Print P2D32V001E ...
Page 204: ...2 APPENDIX F4AE NEF ENGINES Base April 2006 Print P2D32V001E ...