Pin
Description
Wire
code
Max.
Load
Connected to
Remarks
2
Multi-state switch
1238888
Input
15 mA
ALL 23
Limitation 1
st
gear and inhibition reverse gear
Open wire = function active
+24V = function not engaged
Ground = function active
This function is normally enabled with an operator-controlled
momentary switch.
When the function is enabled, the transmission is limited to opera-
tion in only Neutral and (selectable*) low forward range(s).
Operator requests to upshift beyond the maximum* gear range or
to shift into Reverse are ignored by the TCM.
If the function is enabled with Reverse selected on the shift se-
lector, the transmission will shift to Neutral.
If the function is enabled in a forward drive range higher than the
maximum specified gear range*, the TCM will invoke preselect
downshifts until the specified gear range is attained.
The function is disabled when the enabling switch is released.
3
–
1422222
ALL 42
4
PTO active
1431111
Input
15 mA
ALL 43
For special applications - Input from PTO switch .
Open wire = inactive
+24V = active
Ground = inactive
Enabling this function alerts the TCM that PTO operation has been
requested by the operator.
When the input function is enabled, the TCM disrupts the “modu-
lated main pressure” feature in the transmission, resulting in trans-
mission operation at full main pressure.
When the function is enabled and all of the following conditions
exist, the TCM activates Output Function G (PTO Enable Output).
Required operating conditions for enabling of this function are:
●
accelerator position is "low";
●
engine speed and output speed are within Customer Modifi-
able Constant limits.
5
PTO control
1302222
Output
500 mA
ALL 30
For special applications - 24V output to activate the PTO
This output function is activated when use of the PTO has been
requested and all operating conditions required to enable the PTO
have been satisfied.
6
Reserved
7
Reserved
8
Double Automatic
Neutral Input
1171111
Input
5 mA
ALL 17
For special applications - Logic mode "and" mode with pin 9
Open wire = function inactive
+24 V = function active
Ground = function active
The TCM determines this function enable request to be valid only
after receiving two separate input signals.
When properly integrated into the vehicle system, the enabled
function automatically commands the transmission to Neutral when
a supplementary vehicle brake is engaged.
Summary of Contents for Stralis MY 2016
Page 1: ...I S S U E 0 3 2 0 1 9...
Page 3: ...Printed 692 68 697 5 Ed Base 03 2019 UPDATE DATA Section Chapter Description Revision date...
Page 6: ...Printed 692 68 697 5 Ed Base 03 2019...
Page 7: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 1 GENERAL INFORMATION...
Page 8: ...Printed 692 68 697 5 Ed Base 03 2019...
Page 27: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 2 CHASSIS INTERVENTIONS...
Page 28: ...Printed 692 68 697 5 Ed Base 03 2019...
Page 87: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 3 APPLICATIONS OF SUPERSTRUCTURES...
Page 88: ...Printed 692 68 697 5 Ed Base 03 2019...
Page 139: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 4 POWER TAKE OFFS...
Page 140: ...Printed 692 68 697 5 Ed Base 03 2019...
Page 165: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 5 ELECTRONIC SUB SYSTEMS...
Page 166: ...Printed 692 68 697 5 Ed Base 03 2019...
Page 225: ...Printed 692 68 697 5 Ed Base 03 2019 SECTION 6 ADBLUE AND SCRT SYSTEM...
Page 226: ...Printed 692 68 697 5 Ed Base 03 2019...
Page 235: ...Printed 692 68 697 5 Ed Base 03 2019 APPENDIX A STRALIS NP CURSOR CNG LNG...