19
IQ Power Fantom
5201292 Rev A
7. TROUBLESHOOTING
NOTE
– Only qualified service personnel are to perform troubleshooting
tasks.
CAUTION – Electric Shock Hazard
Do not troubleshoot high voltage components with power supply energized.
Disconnect input power before troubleshooting. Troubleshooting must be
performed by a qualified service person.
ATTENTION – Risque De Choc Électrique
Ne pas faire de dépannage des composantes de haute tension avec
alimentation sous tension. Couper l’alimentation électrique avant le
dépannage. Le dépannage doit être effectué par une personne qualifiée.
Operational Check
1. Rub a small strip of plastic film until a static charge is developed (cellophane
works well). The charge can either be measured with an electrostatic fieldmeter
or will be evidenced by the film’s attraction to a grounded metal surface.
2. Pass the film in front of the blower for five seconds at a distance of one foot.
Check for any charge remaining on the film as in step 1.
3. If the static charge has been neutralized, then the device is working properly.
If equipment fails to function properly, contact Simco-Ion Customer Service or your
local Simco-Ion Representative.
NOTE
– Never use a “spark test” to check operation. The ionizing circuit
design of the Fantom makes the “spark test” inconclusive and arcing may
damage the unit.