IQ Power Fantom
5201292 Rev A
Set-Up
If the Fantom Wide Blower is operating free standing (without connection to a
Control Station) set up is simply adjusting the air flow on target and adjusting the
blower fan speed if necessary.
When connected to a Control Station, a variety of information can be checked and
operating parameters may be set for the Fantom.
NOTE
– If the Fantom is connected to a Control Station but the Fantom
power switch is off or power disconnected, the Control Station will display
a fault and basic information for the unit.
To edit or select an operating parameter, tap on pencil icon to right of parameter
description.
Device Name
: A user editable name to identify the specific device (14 character).
Device Type
: A fixed description for the device type (eg. Ionizing air blower)
Operation Mode
: A user selectable operating mode for the ionizing air blower
(Fixed, Manual Narrow, Manual Wide, CLFB).
•
Fixed
- Ionization balance set to zero using the Ion Balance control on unit
(default factory setting).
•
Manual Narrow
- Allows fine manual control of the ion balance over a
narrow range using the IQ Power Control Station. This mode of operation
would only be selected where the material to be neutralized exhibited
consistent charging of one polarity. An electrostatic field meter would be
used to assure neutralization during set-up.
•
Manual Wide
- Allows coarse manual control of the ion balance over
a wide range using the IQ Power Control Station. This This mode of
operation would only be selected where the material to be neutralized
exhibited a challenging and consistent charging of one polarity. An
electrostatic field meter would be used during set-up.
•
CLFB
- Closed-loop Feedback, requires pairing with a downstream IQ Easy
Sensor Bar through the IQ Power Control Station. The sensor bar detects
any voltage imbalance on the material to be neutralized, then transmits this
information to the ionizing blower. The ionizing blower makes incremental
changes to the balance setting until material charges are minimized.
Ionization Output
: The ionization level, in percent.
Ionization Current
: The ionization level in terms of microamps for both positive
and negative ionization.