17
USER MANUAL SPIKA
PROBLEM
PROBABLE CAUSE
SOLUTION
None of the electrical parts work.
The machine is unplugged.
Plug in the machine and
verify shocket power.
Rear switch OFF.
Switch ON.
Front switch position “0”.
Move to “
ICE
” (behind front panel).
All the electrical parts work but not
compressor. (water doesn´t get frozen).
Front switch position “
WASH
”.
Move to “
ICE
” (behind front panel).
No water in tray.
Not incoming water.
Check water supply.
Inlet strain at water valve blocked.
Check an clean.
Not enoug water to end cycle.
Water level probe too low.
Move up (steel rod beside pump).
Defective drain valve
(check drain leak during ice stage).
Disamble and clean.
Shield splash leaks.
Check shield position.
Water overflows tray.
Level probe to high or scaled.
Adjust / clean.
Ice slab empty or too thick.
Desadjusted/scaled thickness probe.
Adjust / clean.
Difficult to release ice slab at harvest.
Unit bad leveled (tilted to back).
Level; down front.
Not uniform flow pattern at evaporator.
Dirty or scaled distributor.
Perform descaling procedure.
Remove an clean distributor (pull
from two clips at distributor sides).
Low production.
Dirty condenser.
Clean (check also incoming
water/air temperature).
Unit stops after few time running.
Safety presostat opens.
Clean air condenser (back).
For further problems call aftersales service.