12
USER MANUAL SPIKA
11) Remove shield.
12) Clean all surfaces of the shield with the cleaner solution using a brush (not a wire brush) or cloth. Rinse all areas
with water.
13) Clean all the interior surfaces of the freezing compartment (including storage bin) with the cleaner solution using
a brush or cloth. Rinse all areas with water.
14) Mix a solution of sanitizer using approved (EPA/FDA) sodium hypochlorite food equipment sanitizer to form a
solution with 100 - 200 ppm free chlorine yield. Below an example to calculate the proper quantity of sanitizer to
add to the water, for a household bleach 12,5%:
15) Sanitize all surfaces of the shield applying liberally the sanitizer solution using a cloth or sponge.
16) Sanitize all the interior surfaces of the freezing compartment (including the storage bin) applying liberally sanitizer
solution, using a cloth or sponge.
17) Return shield to its position.
18) Connect power and water supplies.
19) Fill water reservoir with the sanitizer solution.
20) Switch on machine in order to run water pump. Let solution stand for 20 minutes and switch off.
21) Remove the auxiliary pipe to drain and purge out the sanitizer solution and residue. Replace it. Fill the water
reservoir with water and switch on the machine to allow water to circulate for 5 minutes and then stop the
machine. Repeat this operation two more times to rinse thoroughly.
22) Remove the auxiliary hose to drain the water. Replace it and fill the tray with water to ensure the pump works
properly.
23) Switch on compressor switch (position I).
24) Return the back metal lid and the top panel to their position.
25) Switch on machine and discard the first two harvests.
(2) Cleaning Water Distribution System for Modular Models
1) Set Ice-wash switch to the OFF position (position 0) after ice falls from the evaporator at the end of a harvest
cycle, or set the ice-wash switch to the OFF position and allow the ice to melt off the evaporator.
CAUTION:
Never use anything to force ice from the evaporator. Damage may result.
2) Remove the front panel.
Shield
Front panel
Bleach to add = = 1.2 gr/L *0.133 = 0.16 oz/gal
15
15
% dis
12.5
Summary of Contents for spika
Page 60: ...COD 6487_27 04 2017 ...