en
• Ambient temperature: +0°C to +40°C
• Maximum height above sea level: 1000 meters
• Temperature of pumped liquid: + 1°C to + 35 °C for DOMO series pumps, + 1°C to + 25 °C
for all the other pumps
• Nature of pumped liquid
- Versions with single channel or double channel impeller: clear water, effluent / sewage
containing suspended solids but no chemically aggressive substances or sand
Type
Max solid dia. (mm)
DOMO 7
35
DOMO 10 – 15 – 20
50
DL 80 – 90 – 105
45
DL 109 – 125
50
- Versions with vortex impeller : clear water, effluent / sewage containing suspended solids and
filaments but no chemically aggressive substances or sand
Type
Max solid dia. (mm)
DOMO 7 VX
35
DOMO 10 VX – 15 VX – 20 VX
50
MINIVORTEX – VORTEX
45
DLV 100
50
• Suitable for indoor (basements, cellars, etc.) or outdoor installation (above ground or under-
ground).
• Voltage and frequency of power supply mains must be compatible with pump rating.
(Normally, the power supply for single-phase pumps is 230 V ± 10% 50 Hz, for three-phase
pumps 400 V ± 10% 50 Hz. In any case, refer to the rating plate attached to the pump)
• Maximum number of starts per hour, evenly distributed : read the operating instructions for the
electric pumps
4.1 Lifting stations with electric panel and/or pumps featuring external condenser holder
(additional requirements to those listed above):
• Ambient temperature : +0°C to +40°C
• Maximum relative humidity : 50 % to + 40°C provided no condensation occurs
• Maximum height above sea level : 1000 meters
• Protection class : read the electric panel specifications
For environmental conditions other than those listed above, please contact our Sales and Service Depart-
ment.
Inside the motor of some electric pumps there is non-toxic oil used to facilitate motor cooling. Any
leaks through the mechanical seal can pollute the pumped liquid.
5. Installation
Directions for installers
The installation operations must be carried out by skilled and qualified personnel.
Use adequate equipment and protections. Observe the accident prevention regulations in force.
Lift and handle the product carefully, using suitable hoisting equipment.
Before proceeding with the installation, read these operating instructions and the manual for the
electric pump.
22