Nameplate field
Explanation
RATED FLOW
Rated pump flow, gpm (m
3
/hr)
RATED HEAD
Rated pump head, ft (m)
M.A.W.P. DISCH.
Maximum allowable working discharge pressure, psi (kg/cm
2
)
M.A.W.P. SUCT.
Maximum allowable working suction pressure, psi (kg/cm
2
)
DISCHARGE
Discharge region hydrostatic test pressure, psi (kg/cm
2
)
SUCTION
Suction region hydrostatic test pressure, psi (kg/cm
2
)
YEAR BUILT
Year the pump was built
INSPECTED BY
Quality control identification stamp
ATEX nameplate
Figure 4: ATEX nameplate
Nameplate field
Explanation
II
Group 2
2
Category 2
G/D
Use when gas and dust are present
T4
Temperature class
The code classification marked on the equipment should be in accordance with the specified area where
the equipment will be installed. If it is not, please contact your ITT/Goulds representative before proceed-
ing.
WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure the pump driver and all other auxiliary components meet the required area classifica-
tion at the site. If they are not compatible, do not operate the equipment and contact an ITT
representative before proceeding.
3.2 Nameplate information
16
Model VCW Installation, Operation, and Maintenance
Summary of Contents for Goulds Pumps VCW
Page 1: ...Installation Operation and Maintenance Model VCW ...
Page 2: ......