b) Slide finned tube through the hole on right side of frame.
c)
Install reducer bushing on right side of frame .
d) Thread a second tube fitting (with straight bore) into reducer bushing.
e) Center tube in frame and tighten ferrule nuts on tube fittings.
f)
Install one tube fitting with a stepped bore on each end of tube and tighten ferrule nuts.
6.14 Reassembly of taperbore™ plus seal chamber and
mechanical seal
1.
Apply a liberal amount of an anti-galling compound (Loctite "Nickel Anti-seize") to shaft sleeve (126)
bore and shaft (122).
Figure 44: Application of anti-galling
2.
Slide sleeve (126) onto shaft (122).
3.
Completely lubricate the O-ring in the bore of the mechanical seal sleeve.
4.
Install cartridge seal on sleeve (126).
5.
Rig lifting device to eyebolt in seal chamber (184) and install seal chamber (184) on bearing frame
(228).
6.
Install hex head bolts (370B).
7.
Slide cartridge seal on gland studs (353). Assure that gland studs align with openings in gland, and
that the tap connections are in the correct orientation.
8.
Install gland stud washers (354) and nuts (355) and finger tighten the gland nuts. Do not tighten the
nuts or set seal until after the mixer rotor is adjusted.
9.
After the rotor is installed and clearance is set, secure the mechanical seal as follows:
a) Refer to mechanical seal drawing.
b) Tighten gland nuts (355) evenly.
c)
Tighten set screws in drive collar while setting clips are engaged.
d) Remove setting clips.
6.15 Installation of rotor
1.
Install shaft key (178) on shaft (122) (Fig. 47).
6.14 Reassembly of taperbore™ plus seal chamber and mechanical seal
3501 Installation, Operation, and Maintenance Instructions
51