Figure 46: Transverse stationary vane
2.
Align holes in casing foot (131) with tapped holes on appropriate casing (100) foot bosses. These
are normally the holes facing the baseplate.
3.
Install hex cap screws (370F) and tighten to torque value in
Table 10: Model 3501 Fastener Infor-
.
4.
For 8" mixers, degrease threads in casing (100) inlet flange, and apply ND Industries VIBRA-TITE
thread sealing compound to threads on alignment pin.
5.
Install alignment pin (shank plug) into tapped hole in inlet flange and tighten.
6.17 Installation of back pull-out assembly
NOTICE:
For pumps or back pull-out assemblies supplied with cartridge mechanical seals, the centering
tabs must be in place and tightened, and the set screw collar loosened. Failure to take these
steps could result in damage to the mechanical seal or shaft sleeve.
1.
Adjust rotor (101) so gap between rear rotor shroud vanes and seal chamber (184) is approximately
0.5 mm (.02 in.).
2.
Place casing gasket (351) on seal chamber (184).
3.
Place sling from hoist around frame (228) (Fig. 48).
6.17 Installation of back pull-out assembly
3501 Installation, Operation, and Maintenance Instructions
53