Section 9, Installing the Distribution Module
International Thermal Research
9-13
9.9 Hot water temperature adjustment
The distribution module has the option to adjust the temperature
of the domestic hot water outlet. Standard this temperature is
set at 120F (49°C). In order to adjust the temperature, the front
cover has to be removed. The front cover can be removed by
removing the 6 Philips head screws. The mixing valve adjustment
knob is shown in the figure below.
Figure 9-11: Mixing valve location
The parts inside the module are HOT when in operation. Use
gloves when adjusting the mixing valve.
Turning the knob left (clockwise from top view) will increase the
hot water outlet temperature up to a maximum of 145F (63°C).
Turning the knob right (counter-clockwise) will decrease the hot
water outlet temperature down to minimal 100F (38°C). Mount
the cover back in place after the adjustment.