SYNTHESIZED SETS
USER MANUAL
35
9. CHANGING THE WORKING FREQUENCY (NOT VALID FOR GCFI
VERSIONS)
ATTENTION:
THE WORKING FREQUENCY SHOULD ONLY BE CARRIED OUT BY
AUTHORISED STAFF.
9.1. OPERATION MODE
The system can operate in three modes:
- Mode 1: change of frequency disabled.
- Mode 2: change of frequency in manual mode.
- Mode 3: change of frequency in automatic mode.
ATTENTION:
THE EQUIPMENT IS DELIVERED WITH THE CHANGE OF FREQUENCY IN
AUTOMATIC MODE.
Changing the operation mode:
1) Unlock the STOP BUTTON* and remove the key or turn off the selector switch (or battery).
2) Press the START and UNITS buttons (in COMPACT and BOGGY models) or the START
BUTTON and RIGHT JOYSTICK in the UNITS position (in COMBI and BETON models) at the
same time. Keep them pressed and insert and turn the key or turn on the selector switch (or
insert the battery). Leds
and
will flash simultaneously from one to three times,
indicating the operation mode that has been programmed, which can be:
- Mode 1: change of frequency disabled (one flash).
- Mode 2: change of frequency in manual mode (two flashes).
- Mode 3: change of frequency in automatic mode (three flashes).
Keep the start button pressed, and each time units button or joysticks are activated mode will be
changed successively from mode 1 (change of frequency disable) to mode 2 (change of frequency in
manual mode), from mode 2 to mode 3 (change of frequency in automatic mode), from mode 3 again
to mode 1, etc.
*
Except in Winner emitter, where the STOP BUTTON must be locked.