⑧
Ribbed belt
(Optional)
PM605KT/PM605KT-B Technical documentation
16
4.
Preparation Before Installation
Ribbed belt
Refer to CBK-109 technical documentation for emergency stop.
⑨
Emergency Stop Device
Select the circuit breaker according to the capacity of your 24V DC power supply.
Selecting the proper circuit breaker will provide additional protection to overflow current
situation.
When selecting earth leakage breaker, select inverter compatible type. Some non-
inverter type may incorrectly respond to the high frequency component of the switching
power supply as earth leakage.
When the 24VDC power supply unit has been installed, check that the circuit breaker
and emergency stop switch function properly. Perform operation according to the
following steps.
1) Input to the DC power supply is securely turned ON and OFF when turning ON and
OFF the breaker.
2) Input to this Product (24V DC) is securely turned ON and OFF when turning the
emergency stop switch OFF and ON.
⑨-1
Circuit breaker
check points
⑨-2
Device Operation
Test
Safety precautions
Preparation Before Installation
Check product
Installation
Maintenance
Appendix
Original notice - A1.1
Pitch between the rollers
(mm)
For pulley Ø56mm
60-63
6
4
Ref. 4PJ302-56
Number of teeth
67-70
71-74
77-80
83-87
94-99
100-101
103-107
109-114
122-127
130-135
136-141
150-156
175-182
188-195
234-238
285-289
Ref. 6PJ302-56
Ref. 4PJ314-56
Ref. 6PJ314-56
Ref. 4PJ316-56
Ref. 6PJ316-56
Ref. 4PJ336-56
Ref. 6PJ336-56
Ref. 4PJ346-56
Ref. 6PJ346-56
Ref. 4PJ372-56
Ref. 6PJ372-56
Ref. 4PJ376-56
Ref. 6PJ376-56
Ref. 4PJ388-56
Ref. 6PJ388-56
Ref. 4PJ416-56
Ref. 6PJ416-56
Ref. 4PJ436-56
Ref. 6PJ436-56
Ref. 4PJ442-56
Ref. 6PJ442-56
Ref. 4PJ456-56
Ref. 6PJ456-56
Ref. 4PJ486-56
Ref. 6PJ486-56
Ref. 4PJ536-56
Ref. 6PJ536-56
Ref. 4PJ570-56
Ref. 6PJ570-56
Ref. 4PJ636-56
Ref. 6PJ636-56
Ref. 4PJ746-56
Ref. 6PJ746-56
Pitch
Pitch