⑦
MDR extension cable
(Optional)
An extension cable is required when the distance between the MDR and the
driver card is longer than the MDR cable length.
■
Total length of cable including cable on MDR must not be longer than 3000 mm.
■
Do not use multiple extension cables per MDR.
■
CBK-109 / HBK-608 IB-E04 IB-P02 12P Extension cable
/ / :
■
CBK-109
:
13P Extension cable
(
for Mechanical brake option
)
60
L
±5
Male side
Male side
Female side
Female side
37
60
L
±5
37
37.5
40
φ
5.5
φ
5.5
PM605KT/PM605KT-B Technical documentation
15
4.
Preparation Before Installation
Preparation Before Installation
Safety precautions
Preparation Before Installation
Check product
Installation
Maintenance
Appendix
Original notice - A1.1
Part number
13 Pin extension cable length
ACE-CBK-H1000
L= 1000mm
Part number
12 Pin extension cable length
ACE-CBM-G1200
L= 1200mm
ACE-CBK-H2000
L= 2000mm
ACE-CBM-G2000
L= 2000mm