24
STL-SAT Changeover
© 2018 ITEL SNC
the phone numbers programmed in the system.
If the device exceeds the amount of alarms that can be sent per time unit, additional messages will be
suspended for a period of 2 hours, and "Pause Reset: 0" will appear in the modem window. By resetting the
timer (bring the reset parameter to 1) you can resume sending the message immediately.
2.5.4
IP Settings
If there is the ethernet interface module this page will be present, from here you can view the ip and the
door of the machine.
To make changes to network parameters, access the web page of the device through a internet browser by
typing the ip address displayed and the following login credentials:
User: admin
Password: admin
The ethernet module allows you to connect to the device via the "Xvr programmer" software provided
through the TCP / IP protocol.
2.5.5
Functioning, Alarms and Warninngs
In the second line of the ERRORS menu, alarms or active alerts will be displayed sequentially.
At the same time, the "ALARM" LED on the front panel will blink if there are warnings and no alarms or it
will be lit when there is at least one alarm.
The "Reset" command allows the reset alarm to be reset and will end, if enabled, the bypass mode forced
by the user.
If, even after the reset, there are still active alarms, they will be displayed again, otherwise the "No
errors" string will be displayed.
No errors
: no alarm or warning present
Alarms:
Memory cksum err :
Data errors contained in RDS memory
Memory fault:
communication errors with RDS memory
Memory unformatted:
the memory was replaced and found unformatted
Main audio fault:
the main channel is in alarm condition
Summary of Contents for STL-SAT Changeover
Page 2: ......
Page 5: ...Section 1 Introduction...
Page 15: ...Section 2 Display Function...
Page 27: ...Section 3 Control Software...
Page 49: ...Section 4 GSM SMS Functions...