Waveform
Display Function
Copyright © Itech Electronics Co., Ltd.
21
trigger level can be observed on the screen.
4.2 Adjustment of Measurement Parameters
You can rotate the knob to adjust the vertical calibration, horizontal calibration,
trigger delay and trigger level of the waveform display interface. Detailed steps
are as follows:
Operation steps
1. Press “
” to enter the waveform display interface.
2. In the waveform display interface Press the soft key corresponding to the
“KNOB SEL” parameter and select the parameter to be adjusted. When
“KNOB SEL” is pressed once, the parameter to be adjusted via the knob
will be switched in sequence among U/I/TL/TD/Td.
3. When the parameter is adjusted by rotating the knob, the interface will
display changes of the corresponding value.
4.3 Setting of Trigger Configuration
When you need to enable the trigger function, you should select the trigger
source, trigger mode, trigger slope and other trigger-related configuration.
Detailed steps are as follows:
Operation steps
1. Press “
” to enter the waveform display interface.
2. In the waveform display interface Press the soft key corresponding to the
“TIRG SET” parameter to enter the trigger setting interface, as shown
below.
3. Press the right soft key corresponding to the parameter to select the
required trigger configuration.
Source: trigger source
Mode: trigger mode
Slope: trigger slope