5. OPERATION.
5. OPERATION
5.1. SWITCH FUNCTIONS
Options selectable from the Switch:
STOP
(calibration):
Stops irrigation and fertigation. When selecting another position of the switch irrigation continues from the program
that was stopped.
Best position to calibrate pH and EC sensors.
RUN W:
Irrigation (calibration). In this position of the switch irrigation is active, but not the fertigation. Allows calibration, but
only if the pH and EC sensors are installed in an external sensor holder.
RUN W+F
:
Irrigation and fertigation. Normal position of the switch.
SWITCH
RUN W+F : Water+Fertirrigation
RUN W: Water(calibration)
STOP (calibration)
5.2. REMOTE STOP
Stop and irrigate is controlled from Input1 in Module 1. This function is used by the switch at the STOP position,
so when the contact is closed, the irrigation program continues where it was stop.
WATER CONTROLLER 3000
2
1
3
2
1
3
2
1
3
2
1
3
STOP
RUN
USER'S MANUAL
WATER CONTROLLER 3000