![ITC VISIONS 3000 User Manual Download Page 16](http://html1.mh-extra.com/html/itc/visions-3000/visions-3000_user-manual_2095018016.webp)
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
1
4
EC 31%
PH 86%
mS
m3h
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
CAL
PROG
ALM
CONT
HIST
AUX
mS
m3h
ENT
ENT
3.8.1.2 FLOWMETER CALIBRATION
PRES
TIME
PUMP
PH
EC
Q
Change Units by pr/- and validate by ENT:
m3h
: Water Flow in m3/h
Dosage Flow in l/h
gal
: Water Flow in GPM
Dosage Flow in GPH
3. CONFIGURATION
K-Factor
(pulses/litre or pulses/gallon):
Please refer to Manual Instructions of Flow Meter in accordance with the type and size of the pipes where it is
installed.
Change Value by pr/- and validate by ENT
W.COUNTER
: liters/pulse of a water counter
Q=0
: time when it´s considered there is no flow.
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
CAL
PROG
ALM
CONT
HIST
mS
m3h
AUX
ENT
Change Units by pr/- and
validate by pressing ENT.
CTRL. PH: ACID/ALKALINE
: defines if the pH Control is executed by adding Acid (ACID) or Base (ALKALINE)
EC:1.40:
defines the EC buffer used. It can be modified by pr/-
PH: 4 Time 60s
: defines the pH Buffer and the Stabilization Time for the Sensor Calibration.
3.8.1.3.1 Calibration set up
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
CAL
PROG
ALM
CONT
HIST
AUX
mS
m3h
Q
EC
PH
250
1.05
7.6
A
F02
5.4bar
B
1
4
EC 31%
PH 86%
mS
m3h
3.8.1.3 EC AND PH CALIBRATION
WATER CONTROLLER 3000
USER'S MANUAL
K-factor
(pulse/liter)
Diameter(Inch)
Diameter (mm)
K-factor
(pulse/gallon)
32
75
160
40
90
200
50
110
250
63
125
315 400
1
2 ½
6
1 ¼
3
8
1 ½
4
10
2
5
12
16
78.5
9.2
2.2
45
6.6
1.3
27.4
4.3
0.74
15.7
3.6
0.52 0.27
297
35
8.2
170
25
4.8
104
16.3
2.8
59.5
13.6
2.0
1
Flowmeter Burkert 8020
Flowmeter GF 2536
32
75
160
40
90
200
50
110
250
63
125
315 400
1
2 ½
6
1 ¼
3
8
1 ½
4
10
2
5
12
16
57
12.3
2.0
30
7.6
1.4
18.6
5.3
0.8
15.6
4.0
0.4 0.2
214
47
7.7
113
29
5.2
71.5
20
3.0
59
15.1
1.6 0.9
K-factor
(pulse/liter)
Diameter(Inch)
Diameter (mm)
K-factor
(pulse/gallon)
CHECK
FIRMWARE
SETUP
ENT
SET UP
Kp B: 10
CTRL. PH: ACID
NUM PROG.: 1
EC: 1.40
PH: 4 TIME: 60S
Kp A: 10
Q
Units:
Qtype: HIGH
K-Factor: 2.00
m3h
Q
Units: m3h
Qtype: HIGH
K-Factor:
2.00
Q
Units: m3h
Qtype:
K-Factor: 2.00
HIGH
To configure a water counter, select LOW.
Q
Units: m3h
Qtype:
W.COUNTER: 000.0 l/p
TIME Q=0: 300s
LOW
Q
Units: m3h
Qtype: LOW
W.COUNTER:
TIME Q=0: 300S
000.0 l/p
Q
Units: m3h
Qtype: LOW
W.COUNTER:000.0 l/p
TIME Q=0:
300S
Q
Units: m3h
Qtype:
K-Factor: 2.00
HIGH
16