![ITC VISIONS 3000 User Manual Download Page 11](http://html1.mh-extra.com/html/itc/visions-3000/visions-3000_user-manual_2095018011.webp)
3. CONFIGURATION.
3.3. FILTERS SETUP
FILTERS menu
1.-
STOP WATERING:
YES:
stops irrigation while filters are cleaned.
NO:
irrigation continues while filters are cleaned.
2.-
WHILE WATERING
:
YES:
cleans filters ONLY if there is irrigation.
NO:
cleans the filters no matter if there is irrigation or not.
3.-
OUT:
outputs assign to filters (0-6).
4.-
FREQ:
Frecuency in hours:minutes to clean filters. If FREQ = 00:00, it will only clean when it is ordered through
the input of cleaning filters (Input2).
5.-
CLEAN:
duration of the cleaning in seconds.
6.-
DELAY:
delay time when activating two filters at the same time.
7.-
ADD OUT:
more outputs activated when a filters cleaning starts.
Use “<” / “>” to navigate the menu. Press ENT to save and ESC for not saving.
USER'S MANUAL
WATER CONTROLLER 3000
3.4. MIXERS
Mixers are linked to the fertirrigation program pumps.
MIXERS menu
Number of the dosing pump
Output of the mixer
Activation mode
Time on (minutes)
Frequency
Use “<” / “>” to navigate the menu. Press ENT to save and ESC for not saving.
Select an output for each mixer, each output will be linked to the dosing pump.
CONFIG
PUMPS
FILTERS
MIXERS
EXPRESS PROGRAM
WATERING FACTOR
SET UP
CONFIG
PUMPS
CONFIG
FILTERS
PUMPS
EXPRESS PROGRAM
WATERING FACTOR
SETUP
MIXERS
ENT
MIXERS
1. -- - - - - - - -: - -
2. 12 MAN - - - -: - -
3. 15 PRE 01 - -: - -
4. 16 CON - - - -: - -
5. 17 DIS 01 00:10
6. -- - - - - - - -: - -
CONFIG
PUMPS
FILTERS
MIXERS
EXPRESS PROGRAM
WATERING FACTOR
SET UP
CONFIG
PUMPS
CONFIG
FILTERS
PUMPS
MIXERS
EXPRESS PROGRAM
WATERING FACTOR
SETUP
ENT
FILTER CLEANING
STOP WATERING: NO
WHILE WATERING: YES
OUT:
FREQ.: 00:00
CLEAN: 60 s
DELAY: 30 s
ADD OUT: _ _ +-:00:00
01