USER'S MANUAL
WATER CONTROLLER 3000
3. CONFIGURATION.
5.-
TIME:
irrigation duration.
6.-
Outputs
to activate in the program. 6 is the maximum number of output to activate at the same time for module,
includes pumps and filters.
7.- Pre irrigation time.
8.-
FERT:
Fertirrigation program to activate.
9.- Post irrigation time.
4.-
START:
time of irrigation start
Start times screen to configure up to 15 daily start up.
Priorities
of the program to start are:
1.- Start time of the program.
2.- If the program only has mixer outputs.
3.- Índex of the starting time (If it is the first starting time of the program, the second, etc...).
4.- Lowest program number.
Limit of 6 outputs activated at the same time for module. If more are activated, outputs
with lower number have priority.
When an irrigation program starts, and two or more programs should be activated,
the program with lowest number has priority.