![ITC VISIONS 3000 User Manual Download Page 25](http://html1.mh-extra.com/html/itc/visions-3000/visions-3000_user-manual_2095018025.webp)
4. PROGRAMATION.
4. PROGRAMATION
4.1 EXAMPLES OF IRRIGATION PROGRAM
EXAMPLE 1:
Instalation with 2 pumps, 2 filters, 3 programs, 24 outputs
- 3 irrigation programs
- Reset Time: at 00:00 all the programs not activated yet are reset.
- 2 water pumps assigned to outputs 1 and 2. Delay between pumps start 3 seconds.
- Filter cleaning activates outputs 3 and 4 for 60 seconds with a delay time of 30 seconds between them. It will only
be activated when an irrigation program is activated. There is not a frequency for cleaning filters, so it will only be
activated for the switch input (Input2).
- Irrigation programs will be activaten on Monday, Wednesday and Friday, all run for 2 horas and are activated one
after the other.
- Fertirrigation program is F02 and there is a pre irrigation time and post irrigation time of 5 minutes.
SET UP
06.10.2011 10:00
PROGRAMS: 3
MODULES: 1
W.COUNTER: 000 l/puls
TIME Q=0: 60 s
RESET TIME: 00:00
ENG
PUMPS
OUTP: 01 02
STARTING DELAY: 03 s
SAVE AS
T T S S
STA: 08:00 TIME: 02:00
05 06
05 FERT:02 05
PROG: 01
SAVE AS
T T S S
STA: 12:00 TIME: 02:00
09
05 FERT:02 05
PROG: 03
SAVE AS
T T S S
STA: 10:00 TIME: 02:00
07 08
05 FERT:02 05
PROG: 02
M W F
DAILY PLANNING SCREEN
00 02 04 06 08 10
01 02
Date: 02/11/11
12.07.11
12 14 16 18 20 22
03
01 02
03
00 02 04 06 08 10
01 02
Date: 03/11/11
12.07.11
12 14 16 18 20 22
03
00 02 04 06 08 10
01 02
Date: 04/11/11
12.07.11
12 14 16 18 20 22
03
01 02
03
A D
2011
2
NOV
B C
B E
2011
3
NOV
A D
A C
2011
4
NOV
B E
USER'S MANUAL
M W F
M W F
WATER CONTROLLER 3000
FILTER CLEANING
STOP WATERING: NO
WHILE WATERING: YES
OUT: 03 04
FREQ.: 00:00
CLEAN: 60 s
DELAY: 30 s
ADD OUT: 00:00
25