4.2.2.2 Low Flow
DOSING MODE
Mode:
Low Flow
LF
4.2.2.3 Slow Suction
DOSING MODE
Mode:
Slow Suction
SS
The Low Flow mode (LF) allows to pause the dosing during the discharge
cycle, extendind the dosing time and therefore reducing the flow up to 1%.
The other modes allow to reduce the flow up to 10%.
The Slow Suction mode (SS) reduces the speed during the suction cycle to
improve the precision in the dosing of viscous liquids since it reduces the risk of
cavitation and incomplete fillind of the head.
The maximum flow is reduced to 50%.
Min. Flow 2,40 l/h
Max.Flow 120 l/h
4.2.2.4 Low Pulsation
DOSING MODE
Mode:
Low Pulsation
LP
The Low Pulsation mode (LP) extends the time of the discharge cycle to
minimize the effect ot the pulsatile flow and reduce the overpressures caused
in long discharges.
The maximum flow is reduced depending on the gearbox model (frequency).
Max.Flow 84,0 l/h