iStore - Installation Manual - June 2020
16
Cable connection
• This unit requires an isolating switch as required by local by laws
• If the power cord is damaged, It must be replaced by a qualified electrician
•
Means for disconnection must be incorporated in the fixed wiring in accordance with the
wiring rules
• Local codes including but not limited to AS/NZS 3000 must be adhered to for all electrical work
and be undertaken by a licenced electrician
Inspection before trial running
• Make sure the unit is full of water
• Check the water supply to the tank and pipe connections for possible leaks
• Check that all power connections are secure before switching on
Trial running
• Switch on the unit using the controller
• In the case of any unusual noise, switch the power off and consult your iStore technician
• The parameters have been pre set to a temperature of 60 degrees
Seismic restraints
• Where required the unit must be braced with with seismic restraints according to local
standards. Only applicable in earth-quake zones
Air Flow
• The i-store requires a minimum of 120 cubic meters of natural ventilation to operate
efficiently
•
An example would be an area of 8.0m x 6.3m x 2.4m (a large double garage or open space
under a home)
• External installation is the preferred method to capture the warm ambient air temperature
Air discharge will always be cold
• If unit is being installed internally, provision for fresh air to be introduced shall be provided
450 / 700 m3/h minimum requirement
ECV
HOT WATER RETURN
TD
CHV PLV
IV (TYP)
IV (TYP)