SW-90 RGBW
15-
when power is disconnected to the unit.
5. Each lighting unit needs to have an address set to receive the data sent by the
controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX 512 system should be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
Pin 4/5: Not used.
5.3.2 Channel Mode Setting
Enter menu mode, select
Channel Mode
, press ENTER button to confirm, present channel
mode will blinking on the display, use UP and DOWN button to select
Mode1
(4 channels
mode) or
Mode 2
(5 channels mode) or
Mode 3
(7 channels mode), press ENTER button to
store. Press MENU button back to the last menu or idling one minute to exit menu mode.
5.3.3 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address
from 1 to 512 so that the units can receive DMX signal.
Press MENU button to enter menu mode, select
DMX Address
, press ENTER button to
confirm, the present address will blinking on the display, use UP and DOWN button to
adjust the address from 0 to 512, press ENTER button to store. Press MENU button back to
the last menu or idling one minute to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units.
Channel Mode
Unit 1
Unit 2
Unit 3
Unit 4
4 channels
1
5
9
13
5 channels
1
6
11
16
7 channels
1
8
15
22