Following are a few common problems that may occur during operation. Here are 

some suggestions for easy troubleshooting: 

 

A. The unit does not work, no light and the fan does not work 

1. Check the connection of power and main fuse. 

2. Measure the mains voltage on the main connector. 

3. Check the power on LED. 

 

B. Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and           

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the unit or the previous one. 

4.  Try to use another DMX controller.     

5.  Check if the DMX cables run near or run alongside to high voltage cables that may 

cause damage or interference to DMX interface circuit.   

 

C. Some units don’t respond to the easy controller   

1.  You may have a break in the DMX cabling.   

2.  Check the LED for the response of the master/ slave mode signal. 

 

D. No response to the sound 

1. Make sure the unit does not receive DMX signal. 

2. Check if the sound sensitively is too low.   

 

E. One of the channels is not working well 

1.  The cable connected to the PCB may broken. 

 

  7. Fixture Cleaning   

The cleaning of internal and external optical lenses and/or mirrors must be carried out 

periodically to optimize light output. Cleaning frequency depends on the environment in 

Summary of Contents for SW-90 RGBW

Page 1: ...Stage Wash SW 90 RGBW User Guide Please read these instructions carefully before use...

Page 2: ...anel 5 4 2 Power On Display 6 4 3 Main Function 6 5 How To Control The Unit 13 5 1 Master Slave Built in Preprogram Function 13 5 2 Easy Controller 13 5 3 Universal DMX Controller 14 5 3 1 Connection...

Page 3: ...herwise the unit will be overheated y Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit y It s important to ground the yellow green conduc...

Page 4: ...ot open the unit as there are no user serviceable parts inside y Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the n...

Page 5: ...ight Source total 3W LED x 90pcs Red 18pcs Green 24pcs Blue 24pcs White 24pcs y Voltage AC 230 250V 50 60Hz y Power consumption 291W y Fuse T 6 3A y Beam Angle 15 25 y Dimension 350 x 188 x 325 mm y W...

Page 6: ...ard in the selected functions DOWN To go backward in the selected functions ENTER To confirm the selected functions 4 DMX output For DMX512 link use 3 5 pin XLR plug cable to link the next unit 5 DMX...

Page 7: ...elow Master Mode Present master slave mode Show 1 Present show Mode 1 4Ch Present channel mode is mode 1 4 channels mode Temp 33 C Present detected temperature is 33 C 4 3 Main Function Turn on the un...

Page 8: ...SW 90 RGBW 7...

Page 9: ...ct Show Mode press ENTER button to confirm present show will blinking on the display use UP and DOWN button to select Color Mode or Show Mode Color Mode Select Color Mode press ENTER button to confirm...

Page 10: ...s ENTER button to confirm Press MENU button back to the last menu or idling one minute to exit menu mode White Select White press ENTER button to confirm use UP and DOWN button to adjust White brightn...

Page 11: ...es blackout or No bright mode press ENTER button to store Press MENU button back to the last menu or idling one minute to exit menu mode Back Light Select Back Light press ENTER button to confirm pres...

Page 12: ...R button to confirm Press MENU button back to the last menu or idling one minute to exit menu mode Blue Select Blue press ENTER button to confirm use UP and DOWN button to adjust blue brightness 0 255...

Page 13: ...u mode Green Select Green press ENTER button to confirm use UP and DOWN button to adjust green brightness 125 255 press ENTER button to confirm Press MENU button back to the last menu or idling one mi...

Page 14: ...und activated synchronized light show This function is good when you want an instant show 2 light show In slave mode slave 1 means the unit run as the master unit and slave 2 means 2 light show In ord...

Page 15: ...anched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX ou...

Page 16: ...to select Mode1 4 channels mode or Mode 2 5 channels mode or Mode 3 7 channels mode press ENTER button to store Press MENU button back to the last menu or idling one minute to exit menu mode 5 3 3 Ad...

Page 17: ...SW 90 RGBW 16 5 3 4 DMX 512 Configuration Please refer to below configurations to control the fixtures...

Page 18: ...k the pins on connectors or on PCB of the unit or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage...

Page 19: ...optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provisi...

Page 20: ...Innovation Quality Performance...

Reviews: