ICP 4030 iMC-P
54
/71
January
2018
12 Malfunctions
Fault
Cause
Solution
System will not switch
on
No mains connection
Check circuit power supply
plug, power strip
Main switch not
switched on
Switch main switch on
Fuse faulty
Disconnect mains
plug Replace fuse
POWER button
not working
Cover not closed
Close cover
EMERG-STOP not unlocked
Unlock EMERG-STOP
Fuse faulty
Disconnect mains
plug Replace fuse
Software not working
properly
System not switched on
Switch on system
(main switch)
Output stage not switched on
Switch on output
stage (POWER
button)
Connection not correct
Check cable connections
No communication
via serial interface
Wrong COM port selected
Setting the COM Port
Wrong baud rate selected
Setting the baud rate (19200)
Processing machine
(spindle) does not
work
Incorrect setting in the
spindle module dll
(only DNC mode)
Check and, if necessary,
change settings
Rotary switch on the
machine tool off
Switch on the machine
tool
Traversing widths of
the axes not correct
Spindle pitch does not
correspond to software setting
Change the spindle
pitch in the software
/3/
Step resolution does not
correspond to the setting in the
software (PALPC, Remote)
Change the step
resolution in the
software /3/
Axis referencing is
not executed
correctly
The reference direction and
the corresponding limit switch
are not correct.
Swap limit switch
(remote, @-command)
Referencing is performed on a
deactivated limit switch
Activate limit switch and
change
limit
switch
(remote, @-command) if
necessary
Summary of Contents for ICP 4030 iMC-P
Page 39: ...ICP 4030 iMC P 38 71 January 2018 7 Open processing programme here the NCP file Isel ncp ...
Page 40: ...ICP 4030 iMC P 39 71 January 2018 Result text view ...
Page 41: ...ICP 4030 iMC P Result graphic view 40 71 January 2018 8 for safety sake reference Z axis ...
Page 61: ...ICP 4030 iMC P 69 71 January 2018 14 1 Structure axis systems X Axis ...