ICP 4030 iMC-P
28
/71
January
2018
Analogue - Out
- Sub-D9-pole socket
With this connector, an external frequency inverter and the associated working
spindle can be connected via an analogue 0.... 10V output can be controlled.
Pin
Description
1
+24VDC
2
n.c.
3
n.c.
4
Closer 1 (potential-free contact)
5
Analogue 0 ...10V
6
GND
7
n.c.
8
Closer 1 (potential-free contact)
9
GND
Cover
- Sub-D9-pole socket
At this connection, the door interlock of the connected machine can be integrated
into the safety circuit of the controller.
Pin
Description
1
+ coil opener contact
2
Switch 1.1 (bridge to Pin 3 if no cover is used)
3
Switch 1.2 (bridge to Pin 2 if no cover is used)
4
Switch 2.1 (bridge to Pin 5 if no cover is used)
5
Switch 2.2 (bridge to Pin 4 if no cover is used)
6
- coil opener contact
7 - 9 not used
If no cover/safety door is used, pins 2 and 3 as well as
pins 4 and 5 must be bridged.
Plug connector, 3-pole white 230 V/ 2 A - Work area lighting
E
L
P
N