Troubleshooting
Fault
Cause
Remedy
Equipment can not be turned on
No mains power is available
check the mains circuit,
power plug, multiple socket outlet
Mains switch is not turned on
turn on the mains switch
Fuse is defective
Pull the power plug
replace the fuse (see below)
POWER button does not function
Hood not closed
close the hood
Emergency-Off not released
release Emergency-Off
Fuse is defective
Pull the power plug
replace the fuse (see below)
Software does not work correctly
Equipment not turned on
turn on the equipment (mains switch)
Power stage not turned on
activate power stage (POWER button)
Driver not loaded
install the driver
Connection is not correct
check the cable connectors
Tooling machine (spindle)
Not released by the software
reset the equipment and perform
does not function
a reference movement
Rotary switch at the
turn on the tooling machine
tooling machine is off
Fuse is defective
Pull the power plug
replace the fuse (see below)
Scaling of the axes
Leadscrew pitch does not corres-
Change the leadscrew pitch in the
is not correct
pond to the setting in the software
driver program to 4 or 10 mm
First movements do not correspond EPROM contents a program
Delete the EPROM (s. page 16)
to the programm
Fuse replacement
Pull the power plug before changing any fuse!
The main fuses of the machine
are amenable from the outside. They are located directly
beside the power plug.
Remove the large rear-panel for
changing the other fuses. You find the
main fuse for the motor voltage
in
front of the transformer in the black
plastic holder (
+
: 6.3 A each ).
The remaining fuses are located on
the controller printed circuit board.