80C196KC
1
2
3
jumper field H1
processor
5.2
Adjustments
Setting of the transfer rate (baud rate) and/or of the delay period.
With the H1jumper field, you can set the transfer rate (9 600 or 19 200 bauds) and/or the
delay period of the hood switch (1 or 5 seconds).
- The baud rate is the transfer rate of the serial interface of the computer communicating with
the controller (see the manual for further information).
- Delay is the time passing by between the switching-off of the tooling machine (or the end of
tooling) and the releasing of the COVER button for opening the hood. Delay is used to wait
for the running out of the tooling machine to avoid dangers. Especially with educational and
training applications, 5 seconds of delay are reasonable and should also be set.
Pull the power plug before you place jumpers or remove them.
The jumper field is on the printed circuit board (in the figure on page 19, position 12).
- Ex works, all jumpers are open, i.e. the baud rate is set to 19 200 bauds and the delay to
approx. 1 second.
- A jumper between pin 1 and pin 2 sets a baud rate of
9 600 bauds.
- A jumper pin 1 and 3 between extends the delay period to approx. 5 seconds.
The new setting is taken over with the powering-up of the
machine.
All other jumpers on the printed circuit board must not be
modified!