5.6.6
Buffer tank
Buffer tank is used in overflow type swimming pools to maintain correct
water level in the swimming pool. In this screen, you can see actual water
level of the buffer tank.
H1, H2, H3, H4 active – buffer tank above defined water level for forced
water pumping from tank to the pool.
H2, H3, H4 active – water level in buffer tank is in ideal state.
H3, H4 active – water level in buffer tank is in ideal state.
H4 active – dry run protection alarm active, automatic make up water valve
is activated.
Max. make up time: <value> value in hours. If maximal make up time is
reached, alarm will be raised. Make up water valve will be blocked until reset
alert button is pressed. Perform check if there is not a water leakage or
contact professional.
After performing setup or any changes to this section, click „SAVE SETTINGS” to save configuration to
system.
5.6.7
Service
Access to Service section is password protected and it is intended for professionals. Details about each
section are explained in chapter 3. Installation and Configuration.