LVLØ pH Electrode Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service on pH electrode (calibration,
replacement), set via LVLØ mobile app.
Telegram with value cyclically send to bus every 600s.
10/1/12
LVLØ Redox Electrode Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service on Redox electrode (calibration,
replacement), set via LVLØ mobile app.
Telegram with value cyclically send to bus every 600s.
10/1/13
LVLØ CLF Electrode Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service on Free chlorine electrode
(calibration, replacement), set via LVLØ mobile app.
Telegram with value cyclically send to bus every 600s.
10/1/14
LVLØ UV Lamp Service in Hours Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display hours until UV Lamp replacement, set via LVLØ mobile app.
Telegram with value cyclically send to bus every 600s.
10/1/15
LVLØ Ozone Generator Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service on ozone generator, set via LVLØ
mobile app.
Telegram with value cyclically send to bus every 600s.
10/1/16
LVLØ Salt Chlorine Gen. Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service of salt chlorine generator, set via
LVLØ mobile app.
Telegram with value cyclically send to bus every 600s.
10/1/17
LVLØ Filtration Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service on filtration unit (filter), set via LVLØ
mobile app.
Telegram with value cyclically send to bus every 600s.
10/1/18
LVLØ Heat Pump Service in Day Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display days until next service on heat pump or heat exchanger, set
via LVLØ mobile app.
Telegram with value cyclically send to bus every 600s.
NOTE:
Details are documented in “KNX bus communication” section 6.
For examples of KNX communication see section 6.4.
3.20
Email alerts
3.20.1
Overview
LVLØ system is capable to notify about alerts via emails. Up to two email addresses can be notified via
email. This is useful when the pool professional and pool owner wants to be informed.
Prerequisite for email notifications is to have internet connection working and correct configuration done
in this section as well as in section 5.6.8.3 “Email alert 1” and 5.6.8.4 “Email alert 2”.
3.20.2
Configuration
Email alert setup has to be performed via LVLØ mobile application in Service section; select Email alerts.
Email alerts: <enable/disabled> specify if email alerts should be active. Email addresses configuration is
done via User section, see details in section 5.6.8.3 Email.
3.21
Manual control
3.21.1
Overview
Manual control is dedicated to professionals only as with wrong usage, there is a possibility to cause
damage to technology parts. All technology parts that are possible to operate via manual control are
bypassing automatic and security mechanisms! It is recommended to use manual control only during pool
start or maintenance.
3.21.2
Usage
It is possible to control following equipment.
AUX1: <ON/OFF>
AUX2: <ON/OFF>
Lights: <ON/OFF>