SERVICE MANUAL
© ISA, s.r.o. 2014-2015. All rights reserved.
We reserve the right to change the specification without prior notification.
Always check for new version of this document@
Service manual V1.08 | Nov-2015 | LM0002-EN
Page 63 of 97
The device can be damaged.
Maximum output current is 16A @ 230V AC, 50/60Hz.
Operate the device output only in accordance with the specifications stated in the Technical
Datasheet and service manual.
NOTE:
Total current summary of “UV LAMP”, “SALT CHLORINE GENERATOR”, “OZONE GENERATOR” and “HEATING
PUMP” outputs may not exceed 16A @ 230V AC, 50/60Hz. See details in section 2.2.2 Additional technology.
3.18.3.3
Configuration
UV lamp setup has to be performed via LVLØ mobile application in Service section; select Additional
technology.
UV lamp: <installed/not installed> defines if UV lamp is installed in the pool. If installed, electric power is on
when filtration is running.
3.18.3.4
KNX communication objects
LVLØ KNX communication objects allows to remotely:
Monitor next service interval of UV Lamp - runtime countdown.
Monitor power outage of “UV LAMP” terminal via circuit breaker failure object.
Group
Address
Data Point Name
Data Point Type
Description
10/1/14
LVLØ UV Lamp Service in Hours Status Feedback
display of
value EIS9
4 Byte
R
14.*
Display hours until UV Lamp replacement, set via LVLØ mobile app.
Telegram with value cyclically send to bus every 600s.
10/1/2
LVLØ Circuit Breakers Status Feedback (0=OK, 1,2,4=Err)
display of
value EIS5
2 Byte
R
7.*
Summarized status feedback object to display exact service code in
case of Circuit breakers failure. Telegram with code is sent to bus
cyclically every 600s. Code explanation:
1 - dosing breaker failure (OK/ERR)
2 - filtration breaker failure (OK/ERR)
4 - additional technology breaker failure (OK/ERR)
NOTE:
This output is directly dependent (start/stop) on filtration.
Details are documented in “KNX bus communication” section 6.
For examples of KNX communication see section 6.4.
3.18.4
Ozone generator
3.18.4.1
Overview
LVLØ is equipped with direct high current output for ozone generator device. Ozone eliminates pool odors
common to traditional pool systems and actually oxidizes and destroys oils and other contaminants in
water. Output is turned on automatically without delay after filtration starts and turned off after filtration
stops. Runtime counter can be set to alert for device maintenance.
3.18.4.2
Electrical connection
Terminal output named “OZONE GENERATOR” has direct
230V AC (50/60 Hz) output. Standard output operations is
Normally Open (NO). The output is controlled by an electric
current which is connected to terminal after system trigger
(by starting filtration pump or manually on contactor).
L – Phase (L1)
N – Neutral
PE – Ground